SILICA AEROGEL · THERMAL INSULATION COATING

Insulation measured in millimetres.

A water-based aerogel coating for walls, roofs, tanks and pipelines. One 1–2 mm film does the job of tens of millimetres of conventional insulation — non-combustible, seamless, and spray-applied.

Two grades available — building grade A2, industrial grade A1.
Aerogel thermal insulation coating, 20 kg pail
0.035W/(m·K) Thermal conductivity
A1–A2fire class Non-combustible, two grades
1–2mm Dry film thickness
−20/+120°C Service temperature
Product pail
THE PRODUCT

A coating, not a board.

A white, water-based thixotropic paste. Once cured it forms a flexible, aerogel-filled film that bonds directly to concrete, masonry, metal and most common substrates — no panels, no cladding, no fixings.

Because it is applied like paint, it covers complex geometry that rigid insulation cannot: curved tanks, pipe elbows, valve bodies, and every joint in between.

Form
Water-based viscous paste
Colour
White
Coverage
≈ 1 L/m² per mm of dry film
Shelf life
36 months, sealed
HOW IT WORKS

Heat is stopped in three ways.

Conduction, convection and radiation are blocked in the same 1–2 mm film.

01

Conduction blocked

Over 90 % of the film is air, held inside a silica nano-network. With almost no continuous solid path left, there is very little material for heat to travel through.

02

Convection suppressed

Pores measure 2–50 nm — smaller than the ~70 nm mean free path of air molecules. Gas molecules strike the pore walls instead of circulating, creating a near-vacuum effect inside the film.

03

Radiation reflected

The film reflects infrared in the 8–13.5 μm band — the atmospheric window through which surfaces normally radiate heat to the sky.

Silica aerogel nano-network
Silica nano-network: a solid skeleton that is mostly air.
Pore diameter 2–50 nm
Pore diameter 2–50 nm, below the mean free path of air.
Coating build-up
Build-up: primer, aerogel film, topcoat.
APPLICATIONS

Wherever heat needs to stay put.

Two grades cover the building envelope and industrial equipment.

Building grade A2

Exterior walls, roofs and storage tanks. Blocks solar gain, stops condensation, and keeps the substrate breathable.

Exterior wall
Exterior wall
Roof
Roof
Storage tank
Storage tank

Industrial grade A1

Pipelines, vessels and valves. Cuts heat loss on hot lines, prevents condensation on cold lines, and coats what mineral wool cannot wrap.

Pipeline
Pipeline
Vessel
Vessel
Valve and fittings
Valves & fittings
TECHNICAL DATA

Technical specifications.

Values from factory test reports. Full bilingual and Arabic data sheets are available for download.

ParameterValue
Product nameAerogel Thermal Insulation Coating
BrandRoof Doctor
ColourWhite
FormWater-based viscous paste
Thermal conductivity0.035 W/(m·K)
Fire ratingA2 building · A1 industrialNon-combustible
Dry film thickness1–2 mm can be increased
Coverage≈ 1 L/m² per mm of dry film
Service temperature−20 °C to +120 °C
Drying timeSurface dry in approx. 2–4 hours
ApplicationSpray · roller · brush
StorageCool, dry, sealed — 5 to 35 °C
Shelf life36 months in unopened container
EnvironmentalFormaldehyde-free · benzene-free · water-based

Values based on factory test reports. Actual performance depends on substrate, film thickness and site conditions.

COMPARISON

Aerogel coating vs conventional insulation.

Conventional insulationmineral wool · foam board
Conventional insulation thickness
  • 30–40 mm thickness before performance is reached
  • Panels, fixings and skilled labour
  • Joints and gaps that leak heat
  • Heavy boards that load the structure
  • Fire class B — combustible
  • May contain formaldehyde
Aerogel coatingthis product
Aerogel coating thickness
  • 1–2 mm dry film, full performance
  • Spray, roller or brush
  • Seamless — no joints to leak
  • Lightweight film, negligible load
  • Fire class A1–A2 — non-combustible
  • Formaldehyde-free, benzene-free
APPLICATION GUIDE

Three steps, standard equipment.

1

Prepare

Clean the surface. It must be dry, sound and free of oil, dust and loose material. Prime bare metal as specified.

2

Apply

Spray, roller or brush. Build in 2–4 passes, allowing each coat to reach surface dry before the next.

3

Cure

Build to 1–2 mm dry film. Full thermal performance is reached once the film has cured.

5–35 °CStorage temperature
2–4 hSurface dry between coats
1–2 mmTarget dry film
36 moShelf life, sealed
GET IN TOUCH

Send us your project details.

Tell us the substrate, area and target temperature. We will reply with the recommended grade, film thickness and a quotation.